From the drawing set: we build what’s drawn, to the listing
Detail 5 · 1-HR fire-rated partition (typ.)
- UL Design U419: a 1-hour fire-resistance rating, the listed build-up shown in section, studs at 16″ o.c.
- Built to the listing: board type, layer count and screw pattern as listed. No field substitutions.
- Penetrations firestopped per UL systems; joints staggered, head-of-wall per detail.
- Acoustical ceilings per the RCP: grid and tile to ASTM C635/C636, braced per code.
- Logged in the client portal: submittals, UL directory prints and revisions, the same set the crews run.
| Rating | Assembly | Typical use |
|---|---|---|
| 1 HR | UL U419: 5/8″ Type X, 1 layer each side, studs 16″ o.c. | Corridors, tenant demising |
| 1 HR | Type X + RC channel + insulation, per UL listing | Acoustic separations (STC) |
| 2 HR | UL U411 (typ.): 5/8″ Type X, 2 layers each side | 2-HR corridors, exit stairs, occupancy separations |
| 2 HR | Shaftliner panel system, per UL listing | Elevator and air shafts |
| 1–2 HR | Area separation wall, per UL listing | Multi-family fire walls |
A-101 · FLOOR PLANA-102 · REFLECTED CEILING PLAND-101 · FRAMING ELEVATIONSD-501 · FIRE-RATED DETAILSD-502 · CEILING DETAILSUL DIRECTORY PRINTS
TRINITAS CONSTRUCTION LLC · INTERIOR SYSTEMSSHEET D-501 · FIRE-RATED PARTITIONSSCALE: NTS · REV 0